@msdn=http://search.microsoft.com/search/results.aspx?qu=$$$ @pinvoke=http://pinvoke.net/$$$.htm Summary: The [COMMTIMEOUTS] structure is used in the SetCommTimeouts and GetCommTimeouts functions to set and query the time-out parameters for a communications device. The parameters determine the behavior of ReadFile, WriteFile, ReadFileEx, and WriteFileEx operations on the device. !!!!C# Definition: struct COMMTIMEOUTS { public UInt32 ReadIntervalTimeout; public UInt32 ReadTotalTimeoutMultiplier; public UInt32 ReadTotalTimeoutConstant; public UInt32 WriteTotalTimeoutMultiplier; public UInt32 WriteTotalTimeoutConstant; } !!!!VB Definition: Private Type COMMTIMEOUTS ReadIntervalTimeout As Long ReadTotalTimeoutMultiplier As Long ReadTotalTimeoutConstant As Long WriteTotalTimeoutMultiplier As Long WriteTotalTimeoutConstant As Long End Type !!!!VB .NET Definition: Public Structure COMMTIMEOUTS Public ReadIntervalTimeout As Int32 Public ReadTotalTimeoutMultiplier As Int32 Public ReadTotalTimeoutConstant As Int32 Public WriteTotalTimeoutMultiplier As Int32 Public WriteTotalTimeoutConstant As Int32 End Structure !!!!Members: '''ReadIntervalTimeout''' Maximum time allowed to elapse between the arrival of two bytes on the communications line, in milliseconds. During a ReadFile operation, the time period begins when the first byte is received. If the interval between the arrival of any two bytes exceeds this amount, the ReadFile operation is completed and any buffered data is returned. A value of zero indicates that interval time-outs are not used. A value of MAXDWORD, combined with zero values for both the ReadTotalTimeoutConstant and ReadTotalTimeoutMultiplier members, specifies that the read operation is to return immediately with the bytes that have already been received, even if no bytes have been received. '''ReadTotalTimeoutMultiplier''' Multiplier used to calculate the total time-out period for read operations, in milliseconds. For each read operation, this value is multiplied by the requested number of bytes to be read. '''ReadTotalTimeoutConstant''' Constant used to calculate the total time-out period for read operations, in milliseconds. For each read operation, this value is added to the product of the ReadTotalTimeoutMultiplier member and the requested number of bytes. A value of zero for both the ReadTotalTimeoutMultiplier and ReadTotalTimeoutConstant members indicates that total time-outs are not used for read operations. '''WriteTotalTimeoutMultiplier ''' Multiplier used to calculate the total time-out period for write operations, in milliseconds. For each write operation, this value is multiplied by the number of bytes to be written. '''WriteTotalTimeoutConstant ''' Constant used to calculate the total time-out period for write operations, in milliseconds. For each write operation, this value is added to the product of the WriteTotalTimeoutMultiplier member and the number of bytes to be written. A value of zero for both the WriteTotalTimeoutMultiplier and WriteTotalTimeoutConstant members indicates that total time-outs are not used for write operations. !!!!Notes: If an application sets ReadIntervalTimeout and ReadTotalTimeoutMultiplier to MAXDWORD and sets ReadTotalTimeoutConstant to a value greater than zero and less than MAXDWORD, one of the following occurs when the ReadFile function is called: ->If there are any bytes in the input buffer, ReadFile returns immediately with the bytes in the buffer. ->If there are no bytes in the input buffer, ReadFile waits until a byte arrives and then returns immediately. ->If no bytes arrive within the time specified by ReadTotalTimeoutConstant, ReadFile times out. Documentation: COMMTIMEOUTS@msdn on MSDN '''Or''' http://msdn2.microsoft.com/en-us/library/aa363190.aspx
Edit Structures.COMMTI...
You do not have permission to change this page. If you feel this is in error, please send feedback with the contact link on the main page.